The MUST 12 kW Single-Phase Hybrid Inverter is a low-voltage (48 V) storage inverter for serious home and small-business backup. It blends solar, batteries and grid/generator power, supports export-limit/zero-export (with meter/CTs), offers TOU/peak-shaving, AC-coupling for retrofits, and has an IP65 outdoor-ready enclosure. Supply only—ideal if you already have an installer to handle wiring, protection and commissioning. (mustups.com)
PRODUCT SPECS (SUMMARY)
• Model series: PH1100 EU single-phase; typical variant PH11-12KL1-EU (12 kW). Battery voltage 40–60 V (nominal 48 V). Max charge/discharge current up to 250 A. (mustups.com)
• PV input: up to 15.6 kW DC; PV voltage 370 V nominal (125–500 V window); MPPT range 150–425 V; 3 × MPPT, 1 string per MPPT; PV input current 26 A + 26 A + 26 A. (mustups.com)
• AC side: 12 kW rated (max 13.2 kW), single-phase 220/230 V, PF 0.8 lead…0.8 lag; max continuous AC passthrough 60 A; short-duration peak 2× rated for 10 s. (mustups.com)
• Efficiency & protections: max efficiency 97.6%, MPPT >99%; AFCI (arc-fault), RCMU, anti-islanding, DC Type II / AC Type II–III surge protection (model-table values). (mustups.com)
• Parallel & control: up to 16 units in parallel (on/off-grid); 6 time periods for charge/discharge; Wi-Fi/App monitoring; AC-coupling and diesel-generator charging supported. (mustups.com)
• Enclosure & size: IP65; approx. 446 × 576 × 254 mm; net weight ≈ 31 kg; wall-mount; 5-year warranty. (mustups.com)
WHAT’S INCLUDED (SUPPLY ONLY)
• 1 × MUST 12 kW single-phase hybrid inverter
• Basic user/installation documentation (model/batch dependent)
WHAT’S NOT INCLUDED
• No installation or commissioning
• No batteries, PV modules/mounting, smart meter/CTs
• No AC/DC protection (DBs, breakers, fuses, surge), isolators, MC4s, cables, trunking or comms leads
COMPATIBILITY & NOTES
• Works with 48–51.2 V LiFePO₄ battery stacks via RS485/CAN using the correct MUST ↔ battery profile (comms lead not included). (mustups.com)
• Your installer must configure PV stringing/MPPT, battery limits and all protections to manufacturer specifications.
• For any grid-tied use, comply with your municipality’s SSEG requirements (handled by your installer).
COLLECTION & COURIER
• Collect within 3 hours: Shop 4, 135 Main Rd, Somerset West, Cape Town, 7130
• Same-day courier available nationwide (subject to cut-off, stock confirmation and courier availability)




There are no reviews yet.